| 1. Install pump near the suction water level
 
 1-1 Suction head is varible to the pump, but generally if the 
                  suction head is higher then 7~8m suction
 Will be impossible.
 
 1-2 The larger the diamerter of pipe is, the slower becomes 
                  the flow velocity. So because loos is
 Reduced in case of larger diametem suction head is also increased.
 
 2. Suction pipe shll be installed highest on the side of pump, 
                  and be installed iow by inclining it toward
 The suction water level. Therer is no problem if the water level 
                  on the side of suction is higher than
 The pump, but if there is any place(Wform) where the pipe rises 
                  up and fall down back even though
 the pipe is installed lower than pump in piping the side of 
                  suction, the pump will not work.
  3. Set up the center of coupling exactly before operating 
                    pump because the center of motor and pump Has been fixed by the manufacturer, it is necessary to correspond 
                    them again.
  4. Fix the center of coupling bolt, and be sure to separate 
                    the couplings at an interval of 3~5mm. Be Sure to screw the boll and not of coupling fast, because they 
                    may be loosened in the operation.
  5. in case that there is any oil ring in metal or bearing 
                    parts, be sure to check that it turns smoothly immersed deep in lubricant.
  6.Be sure to check whether the pump and the motor rotate 
                    in the same direction.  7. Fist prime the pump just before operation it, and if 
                    water does not flow, stop the operation immediatelyAnd prime the pump.
  8. The pump will be broken if you rotate it in the reverse 
                    direction, so the rotation in the reverse direction is prohibited adsolutely.
  9. In case of a general pump, open the delivery valve gradually, 
                    but in case of axial flow pump, open theValve fully before the operation.
 10. check whether ther occurs overload, by checking the noise 
                    vibration oil ring and measuring the Current.
 
 
 
 
 
 
 |